Enterasys Enterasys SecureStack B2 B2G124-24 Especificações Página 65

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 600
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 64
show system
SecureStack B2 Configuration Guide 3-13
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetthemethodusedtoacquireanetworkIPaddresstoDHCP.
B2(su)->set ip protocol dhcp
show system
Usethiscommandtodisplaysysteminformation,includingcontactinformation,powerandfan
traystatusanduptime.
Syntax
show system
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
Thisexampleshowshowtodisplaysysteminformation:
B2(su)->show system
System contact:
System location:
System name:
Switch 1
--------
PS1-Status PS2-Status
---------- ----------
Ok Not Installed and/or Not Operating
Fan1-Status Fan2-Status
----------- -----------
Ok Ok
Temp-Alarm
-----------
off
Thermal Threshold: 58%
Temp alarm max threshold: 100%
Temp alarm trap: disabled
Temp alarm syslog: disabled
Uptime d,h:m:s Logout
-------------- -------
0,20:36:49 0 min
Vista de página 64