clear / set spantree spanguardlock
SecureStack B2 Configuration Guide 9-29
clear / set spantree spanguardlock
UseeitherofthesecommandstounlockoneormoreportslockedbytheSpanningTree
SpanGuardfunction.WhenSpanGuardisenabled,itlocksportsthatreceiveBPDUswhenthose
portshavebeendefinedasedge(user)ports(asdescribedinsetspantreeadminedgeon
page 9 39).
Syntax
clear spantree spanguardlock port-string
set spantree spanguardlock port-string
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtounlockportfe.1.16:
B2(rw)->clear spantree spanguardlock fe.1.16
show spantree spanguardtrapenable
UsethiscommandtodisplaythestateoftheSpanningTreeSpanGuardtrapfunction.
Syntax
show spantree spanguardtrapenable
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Example
ThisexampleshowshowtodisplaythestateoftheSpanGuardtrapfunction:
B2(ro)->show spantree spanguardtrapenable
Spanguard SNMP traps are enabled
portstring Specifiesport(s)tounlock.Foradetaileddescriptionofpossibleportstring
values,refertoPortStringSyntaxUsedintheCLIonpage 72.