Enterasys C2RPS-SYS Guia de Instalação

Consulte online ou descarregue Guia de Instalação para Comutadores de rede Enterasys C2RPS-SYS. Enterasys C2RPS-SYS Installation guide [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Enterasys
®
SecureStack
C3
Gigabit Ethernet Switches
Hardware Installation Guide
C3G124-24
C3G124-48
P/N 9034276-01
7.5x9-inch cover with bleed on 4 sides
Vista de página 0
1 2 3 4 5 6 ... 77 78

Resumo do Conteúdo

Página 1 - SecureStack

Enterasys® SecureStack™ C3Gigabit Ethernet SwitchesHardware Installation GuideC3G124-24C3G124-48P/N 9034276-017.5x9-inch cover with bleed on 4 sides

Página 2

viii 3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateandfederalcourtsoftheCommonwealthofMas

Página 3 - Personal vorgenommen werden

ix8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramareofcriticalvaluetoEnterasysand,ac

Página 5 - HAZARDOUS SUBSTANCES

xiContentsAbout This GuideWho Should Use This Guide ...

Página 6 - (Circuit Breakers)

xiiConnecting AC and RPS-SYS Power ...3-15AC Power ...

Página 7

xiiiFigures1-1 C3G124-24 Stackable Switch ...1-21-2 C3G12

Página 9 - FIRMWARE LICENSE AGREEMENT

SecureStack C3 Installation Guide xvAbout This GuideThisguideprovidesanoverview,installationandtroubleshootinginstructions,andspecification

Página 10

How to Use This Guidexvi About This GuideHow to Use This GuideReadthroughthisguidecompletelytofamiliarizeyourselfwithitscontentsandgainan

Página 11

Conventions Used in This GuideSecureStack C3 Installation Guide xviiConventions Used in This Guide Thefollowingconventionsareusedinthisguide:N

Página 13 - Contents

Getting Helpxviii About This GuideGetting HelpForadditionalsupportrelatedtotheswitchesorthisdocument,contactEnterasys Networksusingoneof

Página 14 - Appendix A: Specifications

SecureStack C3 Installation Guide 1-11IntroductionThischapterintroducestheC3G124‐24andC3G124‐48 st ackableswitches.OverviewTheC3G124‐24and

Página 15

Overview1-2 Introduction•SFPslotsthatprovideyouwiththeoptionofinstallingSmallFormPluggable(SFP)Mini‐GBICsfor1000BASE‐SX/LXfiber‐optic

Página 16

OverviewSecureStack C3 Installation Guide 1-3Figure 1-2 C3G124-48 Stackable SwitchHigh-Speed Stack ConnectionsTheswitcheshaverear‐panelconnector

Página 17 - About This Guide

Connectivity1-4 IntroductionConnectivityTheswitchconnectstoEthernetnetworksorworkstationsviathefixedfrontpanelRJ45connectorsandfourup

Página 18 - Related Documents

Standards CompatibilitySecureStack C3 Installation Guide 1-5Switch Configuration Using CLI CommandsTheCLIcommandsenableyoutoperformmorecomple

Página 19

LANVIEW Diagnostic LEDs1-6 Introduction

Página 20 - Getting Help

SecureStack C3 Installation Guide 2-12Network RequirementsBeforeinstallingthedevice,reviewtherequirementsandspecificationsinthischapter.1

Página 21 - Introduction

100BASE-TX Network2-2 Network Requirements100BASE-TX NetworkWhenconnectinga100BASE‐TXsegmenttooneofthefixedports(1 through24onC3G124‐24,

Página 22 - C3G124-24

SecureStack C3 Installation Guide 3-13Hardware InstallationThischapterprovidesinstructionstoinstalltheC3G124 ‐24andC3G124‐48.Unlessotherwi

Página 23 - High-Speed Stack Connections

iNoticeEnterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthisdocumentanditswebsitewitho

Página 24 - Management

Considerations Prior to Installation3-2 Hardware InstallationConsiderations Prior to InstallationWheninstallingtheswitch,notethefollowing:•Befor

Página 25 - LANVIEW Diagnostic LEDs

Installing Optional Mini-GBICsSecureStack C3 Installation Guide 3-3Installing Optional Mini-GBICs ThissectiondescribeshowtoinstallMini‐GBICsin

Página 26 - 1-6 Introduction

Installing Optional Mini-GBICs3-4 Hardware InstallationInstallationToinstallaMini‐GBICthathasanMT‐RJconnector,refertoFigure 3‐3,orforaM

Página 27 - Network Requirements

Installing Optional Mini-GBICsSecureStack C3 Installation Guide 3-5Figure 3-4 Mini-GBIC with LC ConnectorRemoving the Mini-GBICToremoveaMini‐GBIC

Página 28 - 1000BASE-T Network

Installing the Switch on a Flat Surface3-6 Hardware Installation2. Removethe cablesconnectedtotheMini‐GBIC.3. Locatethereleasetabunderthef

Página 29 - Hardware Installation

Installing the Switch on a Flat SurfaceSecureStack C3 Installation Guide 3-7Figure 3-5 Chassis Bottom, Rubber Feet Placement4. Removethe protectiv

Página 30 - Unpacking the Switch

Installing the Switch on a Flat Surface3-8 Hardware InstallationIfyouareinstallingseveralswitchesinastack,proceedto“ConnectingHigh‐SpeedS

Página 31 - Preparation

Rack Mounting the SwitchSecureStack C3 Installation Guide 3-9Rack Mounting the Switch Toinstalltheswitch ina19‐inchrack,youneed:•Tworackmo

Página 32 - Installation

Rack Mounting the Switch3-10 Hardware InstallationAttaching Brackets and Installing in RackProceedasfollowstoinstalltheswitchintoa19‐inchrac

Página 33 - Removing the Mini-GBIC

Connecting High-Speed Stacking CablesSecureStack C3 Installation Guide 3-11Connecting High-Speed Stacking CablesThestackofswitchescanbeconnecte

Página 34 - Installing the Rubber Feet

ii REGULATORY COMPLIANCE INFORMATIONFEDERAL COMMUNICATIONS COMMISSION (FCC) NOTICEThisdevicecomplieswithPart15oftheFCCrules.Operationissub

Página 35 - referto

Configuring Switches in a Stack3-12 Hardware InstallationFigure 3-9 High-Speed Stacking Cable ConnectionsAfterconnectingthecablestothestacking

Página 36 - 3-8 Hardware Installation

Configuring Switches in a StackSecureStack C3 Installation Guide 3-13Onceinstalledinastack,theswitchesbehaveandperformasasingleswitch.A

Página 37 - Rack Mounting the Switch

Configuring Switches in a Stack3-14 Hardware InstallationRecommended Procedures for New and Existing StacksInstalling a New Stackable System of Up to

Página 38 - 3-10 Hardware Installation

Connecting AC and RPS-SYS PowerSecureStack C3 Installation Guide 3-15Adding a New Switch to an Existing StackUsethefollowingproceduretoinstalla

Página 39

Connecting AC and RPS-SYS Power3-16 Hardware InstallationFigure 3-10 Switch Rear View3. ObservethatthepowerCPULED(notshown),locatedonthefr

Página 40 - 3 STACK UP connector

Connecting AC and RPS-SYS PowerSecureStack C3 Installation Guide 3-17SecureStack Redundant Power SystemIfyouareinstallinganoptionalredundantpo

Página 41

Connecting to Console Port for Local Management3-18 Hardware InstallationConnecting to Console Port for Local ManagementThissectiondescribeshowto

Página 42 - Important

Connecting to Console Port for Local ManagementSecureStack C3 Installation Guide 3-19Figure 3-11 DB9 Male Console Port Pinout AssignmentsConnecting

Página 43 - AC Power

Connecting to Console Port for Local Management3-20 Hardware InstallationFigure 3-12 Connecting an IBM PC or CompatibleConnecting to a VT Series Term

Página 44 - 3-16 Hardware Installation

Connecting to Console Port for Local ManagementSecureStack C3 Installation Guide 3-21Figure 3-13 Connecting a VT Series TerminalConnecting to a Mode

Página 45 - Stack Manager Selection

iiiELECTROMAGNETIC COMPATIBILITY (EMC)Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,EN61000‐3‐2,

Página 46 - What Is Needed

Connecting to the Network3-22 Hardware InstallationFigure 3-14 Connecting to a ModemConnecting to the NetworkThefollowingprocedurescoverthecable

Página 47

Connecting to the NetworkSecureStack C3 Installation Guide 3-232. Connectthetwistedpairsegmenttotheswi tchbyinsertingtheRJ45connectoron

Página 48 - 3-20 Hardware Installation

Connecting to the Network3-24 Hardware InstallationRepeatallstepsaboveuntilallconnectionshavebeenmade.Figure 3-16 Four-Wire Crossover Cable

Página 49 - Connecting to a Modem

Connecting to the NetworkSecureStack C3 Installation Guide 3-25Figure 3-18 Eight-Wire Crossover Cable RJ45 Pinouts for 10/100/1000BASE-TXFigure 3-19

Página 50 - Connecting UTP Cables

Connecting to the Network3-26 Hardware InstallationConnecting Fiber-Optic Cables to MT-RJ PortsThissectioncontainstheproceduresforconnectinga1

Página 51 - 1 2 3 4 5 6 789 10 11 12

Connecting to the NetworkSecureStack C3 Installation Guide 3-27.2. InserttheMT‐RJcableconnectorintotheMT‐RJconnectoruntilitclicksintopla

Página 52 - 3-24 Hardware Installation

Connecting to the Network3-28 Hardware Installation4. VerifythatalinkexistsbycheckingthattheportLink/ActivityLEDison(blinkinggreenors

Página 53 - 1000BASE-TX

Connecting to the NetworkSecureStack C3 Installation Guide 3-29Thetransmitstrandfromaswitchportconnectstothereceiveportofafiber‐opticG

Página 54 - 3-26 Hardware Installation

Connecting to the Network3-30 Hardware InstallationFigure 3-21 Cable Connection to LC Fiber-Optic Connectors3. Plugtheotherendofthecableintot

Página 55

Completing the InstallationSecureStack C3 Installation Guide 3-31Completing the InstallationAfterinstallingtheswitchandmakingtheconnectionsto

Página 56 - 3-28 Hardware Installation

iv ѻѻક䇈ᯢк䰘ӊSupplement to Product Instructions ᳝↦᳝ᆇ⠽䋼៪ܗ㋴(Hazardous Substance) 䚼ӊৡ⿄(Parts) 䪙3E∲+J䬝&G݁Ӌ䫀&U໮⒈㘨㣃3%%໮⒈Ѡ㣃䝮3%&apo

Página 57

Completing the Installation3-32 Hardware Installation

Página 58 - 3-30 Hardware Installation

SecureStack C3 Installation Guide 4-14TroubleshootingThischapterprovidesinformationconcerningthefollowing:Thisdevicecontainsabatterythati

Página 59 - Completing the Installation

Using LANVIEW4-2 TroubleshootingUsing LANVIEWTheseswitchessupporttheEnterasys Networksbuilt‐inLANVIEWLEDvisualdiagnosticandstatusmonitorin

Página 60 - 3-32 Hardware Installation

Using LANVIEWSecureStack C3 Installation Guide 4-3Table 4-3 LANVIEW LEDsLED Color State Recommended ActionCPU Off Power disconnected. If the LED rema

Página 61 - Troubleshooting

Using LANVIEW4-4 TroubleshootingUP Off No valid connection to switch stack down connector.1. Make sure the switch connected to the stack down connecto

Página 62 - Using LANVIEW

Troubleshooting ChecklistSecureStack C3 Installation Guide 4-5Troubleshooting ChecklistIfthedeviceisnotworkingproperly,refertoTable 4‐4for

Página 63 - Table 4-3 LANVIEW LEDs

Troubleshooting Checklist4-6 TroubleshootingCannot contact the switch through in-band management.IP address not assigned. Refer to the SecureStack C3

Página 64 - 4-4 Troubleshooting

Using the Reset SwitchSecureStack C3 Installation Guide 4-7Using the Reset SwitchIfyouforgettheswitchloginpassword,usetheResetswitchtores

Página 65 - Troubleshooting Checklist

Using the Reset Switch4-8 Troubleshooting

Página 66 - 4-6 Troubleshooting

SecureStack C3 Installation Guide A-1ASpecificationsThisappendixprovidesinformationaboutthefollowing:Enterasys Networksreservestherighttoc

Página 67 - STACK DOWN

vVCCI NOTICEThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformationTechnologyEquipment(VCC

Página 68 - 4-8 Troubleshooting

Switch SpecificationsA-2 SpecificationsC3G124-48RJ45ports 1 through 48 Forty-eight, 10BASE-T/100BASE-TX/1000BASE-T compliant ports with auto-sensing

Página 69 - Specifications

Mini-GBIC Input/Output SpecificationsSecureStack C3 Installation Guide A-3Mini-GBIC Input/Output SpecificationsTheMini‐GigabitEthernetCard(Mini‐G

Página 70 - A-2 Specifications

Gigabit Ethernet SpecificationsA-4 SpecificationsGigabit Ethernet SpecificationsThefollowingspecificat ionsfortheMini‐GBICsshowninTable A‐3th

Página 71

Gigabit Ethernet SpecificationsSecureStack C3 Installation Guide A-5MGBIC-LC09 Specifications (1000BASE-LX)MGBIC-08 Specifications (1000BASE-ELX) Tab

Página 72

Gigabit Ethernet SpecificationsA-6 SpecificationsMGBIC-02 Specifications (1000BASE-T)Table A-10 MGBIC-08 Operating RangeItem 1550 nm Range9 or 10 µm S

Página 73

Console Port Pinout AssignmentsSecureStack C3 Installation Guide A-7Console Port Pinout AssignmentsTheConsoleportisaDB9serialcommunicationspo

Página 74 - Item Specification

Regulatory ComplianceA-8 Specifications

Página 75

Index-1IndexNumerics1000BASE-SX/LX network connectionsrequirements for 2-21000BASE-Trequirements for 2-2100BASE-TXrequirements 2-210BASE-Tconnection 3

Página 76 - A-8 Specifications

Index-2UTP 4-wire crossover cable 3-24UTP 4-wire straight-through cable 3-24UTP 8-wire crossover cable 3-25UTP 8-wire straight-through cable 3-25Power

Página 77

vi DECLARATION OF CONFORMITYApplicationofCouncilDirective(s): 89/336/EEC73/23/EECManufacturer’sName: Enterasys Networks, Inc.Manufacturer’sAddres

Página 78

viiENTERASYS NETWORKS, INC.FIRMWARE LICENSE AGREEMENTBEFOREOPENINGORUTILIZINGTHEENCLOSEDPRODUCT,CAREFULLYREADTHISLICENSEAGREEMENT.Thisdocum

Comentários a estes Manuais