Gigabit Ethernet Specifications
A-6 Specifications
A.3.4 MGBIC-08 Specifications (1000BASE-ELX)
Table A-8 MGBIC-LC09 Operating Range
Item
Modal Bandwidth @
1300 nm
Range
62.5 µm MMF 500 MHz/km 2-550 Meters
50 µm MMF 400 MHz/km 2-550 Meters
50 µm MMF 500 MHz/km 2-550 Meters
10 µm SMF N/A 2-10,000 Meters
Table A-9 MGBIC-08 Optical Specifications
Item
Transmit Power (minimum) -0 dBm, min. +2 dBm, typical +5 dBm, max.
Receive Sensitivity -24 dBm, min. -26 dBm, typical
Maximum Input Power -3 dBm
Link Power Budget
1
(Full Duplex Only)
1. The maximum drive distance (up to 70 km) depends on the quality of the installed single-mode fiber-optic
cable segment. Use the Link Power Budget to calculate the maximum cable length of the attached segment.
The Link Power Budget must not exceed those specified in this table. The MGBIC-08 input power must not
exceed -3 dBm. Otherwise, saturation could occur.
23 dB 28dB, typical
Table A-10 MGBIC-08 Operating Range
Item 1550 nm Range
9 or 10 µm SMF N/A 70,000 Meters