Connecting Stacking Cables
3-8 Hardware Installation
Figure 35showsanexampleofafourhighstackconnectedinaclosedloop
configuration.AllSTACKDOWNandSTACKUPconnectorsareusedintheinstallation.
ThestackingcableconnectionsarefromtheSTACKDOWNconnectorofoneswitchto
theSTACKUPconnectorofthenextswitchup
inthestack.Astackingcableconnection
fromtheSTACKDOWNconnectoroftheswitchatthetopofthestacktotheSTACKUP
connectoratthebottomofthestackclosestheloop.Inadaisychainconfiguration,one
cableconnectionisnotmade.
Figure 3-5 Stacking Cable Connections
Afterconnectingthecables
tothestackingports,proceedtoConfiguringSwitchesina
Stackonpage 39forinstructions.
1 Category 5 or better UTP cable 4 STACK UP connector at top of stack
2 STACK UP connector 5 STACK DOWN connector at bottom of
stack
3 STACK DOWN connector