VLAN Configuration Command Set
Assigning Port VLAN IDs (PVIDs) and Ingress Filtering
6-16 SecureStack B2 Configuration Guide
6.3.3.4 show port ingress filter
Use this command to show all ports that are enabled for port ingress filtering, which limits incoming
VLAN ID frames according to a port VLAN egress list. If the VLAN ID specified in the received
frame is not on the port’s VLAN egress list, then that frame is dropped and not forwarded.
show port ingress-filter [port-string]
Syntax Description
Command Defaults
If port-string is not specified, ingress filtering status for all ports will be displayed.
Command Mode
Read-Only.
Example
This example shows how to display the port ingress filter status for Fast Ethernet ports 10 through
15 in unit 1. In this case, the ports are disabled for ingress filtering:
port-string (Optional) Specifies the port(s) for which to display ingress
filtering status. For a detailed description of possible
port-string values, refer to Section 3.1.1.
B2(rw)->show port ingress-filter fe.1.10-15
Port State
-------- ---------
fe.1.10 disabled
fe.1.11 disabled
fe.1.12 disabled
fe.1.13 disabled
fe.1.14 disabled
fe.1.15 disabled